Edit page titleCentros ® and CentrosFLO ® hemodialysis catheter -
Edit meta descriptionCentros and CentrosFLO long-term dialysis catheter with precast bent tips, catheter port can be centered in the blood vessels in the middle.

Close the edit interface

Centros ® and CentrosFLO ® hemodialysis catheter

Ask for information

The firstCentrosAnd the side holes (no)CentrosFLO ™(with side holes)Long-term hemodialysis catheterA self-centering curved tip, can automatically catheter port in the middle of their blood vessels, to maintain optimal blood flow and minimum recirculation rate, and improve overall performance.15 f catheter designed by Dr Stephen Ash, with larger lumen, which can realize the flow rate of the 450 mL/min.

Video library

CentrosFLO ® long-term hemodialysis catheter

Features and benefits

Centered on performance

Merit Medical high-performance CentrosFLO ® long-term hemodialysis catheter into account when the design performance, security and ease of use.New self-centering curved tip catheter in the arteries and veins have greater separation between tip.It is designed to optimize catheter unobstructed, and keep in the center of the blood vessels through the catheter tip and away from the vessel wall to reduce the fibrin sheath formation, thrombosis, and vascular wall block.Fibrin sheath is a common cause of catheter dysfunction, in a remove or replace the study of hemodialysis catheter, 76% of patients with fibrin sheath.1, 2, 3CentrosFLO specially designed for performance, safety, and ease of use.

Preforming curved tip

In the superior vena cava (SVC) and right atrium (RA) border stability and center pipe.

The distal side holes veins and arteries

Reduce pressure in the tube cavity and catheter tips to the possibility of blood vessel walls.

Ouchi cavity

Allows velocity of up to 450 mL/min.

security

Noninvasive catheter tip design

Minimize piercing or blood vessel walls stimulates.

Non traumatic tube tunnels

To load faster catheters, and won't cause risk to the catheter tip.

A variety of tube length configuration

To adapt to the changes in patients with anatomical structure.

The results of the study

Dr Sarvan Balamuthusamy recently conducted a retrospective study compared the self-centering split cutting-edge hemodialysis catheter tunnel and the performance of the symmetric tip catheter.The results show that the split self-centering tip catheter after 3 months are statistically higher patency rate, a slight advantage in clearance and blood flow.4

Center of figure

1Average follow-up period of three months
2The average clearance and average blood flow not including catheter unobstructed of the patient's data.
3NSD = no statistical significance, p > 0.05 (t test)

1Crain, Sir, horton, MG, Mewissen, MV.The fibrin sheath complicate the central venous catheter.AJR. 171, 1998;341:346 - XNUMX.
2Forauer AR, Theoharis GA, Dasika NL.Jugular vein catheter placement: the pig model of the histological features of catheter-related (fibrin) sheath and development.Radiation.240, 2006;2(427)434-XNUMX。
3Alomari, AI, Falk, a. tunneled hemodialysis catheter removal or replacement of natural history: A single agency of experience.Jewell.2007;18:227-235。
4Balamuthusamy s. self-centering, divided than symmetric tunneled hemodialysis catheter tip tip catheter has better flowing: single center were retrospectively analyzed.The quick dialing.On 20, 2014, 2014.The electronic on XNUMX XNUMX 20 years.
Carbothane ® is Lubrizol Advanced Materials, Inc., a registered trademark.

The document

Check the manual and instructions, learn about Centros ® and CentrosFLO ® hemodialysis catheter for more information.

In the load...

The order information

The trademark