Aspira ® drainage system

Ask for information
The drainage system Aspira - Merit of Medical care

Compassionate treatment

Aspira drainage system is a kind of tunnel catheter for a long time, for from the pleural effusion or peritoneal cavity drainage, to relieve symptoms associated with pleural effusion or malignant ascites.

Video library

ASPIRA drainage system: the ground services

In this useful services in the video, watching we explain how to use your care Aspira drainage system and drainage liquid, how to mend the catheter exit site and how to properly discard liquid and used items.We also provide answers to common questions.Aspira drainage system is a kind of tunnel catheter for a long time, for from the pleural effusion or peritoneal cavity drainage, to relieve symptoms associated with malignant pleural effusion or ascites.

ASPIRA: insert peritoneal catheter

Watch the Aspira peritoneal drainage catheter insertion process step by step instructions.

ASPIRA: use the insert tray

Merit Medical product manager Logan Clifford serve Aspira drainage system is inserted into the tray.He outlined the tray and its components are introduced, and what you can expect when using the product.

Features and benefits

A new kind of freedom

Aspira drainage system is a kind of compassionate treatment options, family is suitable for end-stage cancer patients with pleural effusion and malignant ascites.Aspira allow patients to manage their symptoms in the home, which do not need to frequently go to the hospital.

Patient comfort

With siphon aided design can produce consistent pressure based on the gravity flow, thereby reducing discomfort to a minimum.

Easy to use

After drainage tube is connected to the catheter valve, drainage gently squeezing can be started.Using Aspira drainage system, there won't be the risk of accidental release of vacuum.Through an extrusion to activate manual pump vacuum.

Drainage faster

Faster drainage velocity means that patients with longer time to rest.


During the drainage pressure more stable

Aspira drainage system designed for use in the case of without the use of high pressure quick drainage.Consistent with the low vacuum pressure is better than that of high vacuum pressure can lead to patient discomfort.

68%
Higher average
The velocity
2, 3

Simulation tests show that the Aspira drainage system hasThe average flow rate increased by 68%Than PleurX®The drainage system.2, 3In addition, unlike PleurX drainage system, Aspira show consistent pressure and flow rate, the latter has the very high initial vacuum degree and falling fast.3

Aspira - higher than Pleurex drainage system average flow rate and a more consistent pressure


72%
larger valve1">72%
A larger valve1

67%
more fenestrations4">67%
More open the window4

Aspira drainage system more open the window4And a larger valve1(compared with PleurX drainage system).

Aspira has a larger valve and more fenestrations than PleurX">Compared with PleurX Aspira has a opening of the valves of the more and more


The placement of than PLEURX system has higher flexibility

Aspira drainage system has three methods of placement option (anterograde and retrograde and online), and a variety of suite options, designed to meet the needs of clients and patients, than PleurX the placement of drainage system to provide you with more flexibility.

Enhanced tunnel design

Aspira Tunneler - enhanced design

  • Forging and bending channels
  • Channel is 37% longer than PleurX of the channel, can be flexible4

With valve drainage device

With a strip type sheathed Aspira Vavled introduced
  • Peel type guiding sheath helps reduce placed fluid leakage and/or in the process of air suction4

Replaceable valve

Aspira replaceable valve
  • Without change the catheter replacement valves

With enhanced

Strengthen the tube core - Aspira preinstalled
  • Strengthen the catheter for insertion
  • With the provincial - Glide ™ coating tube needle, aimed at reducing the fluid leakage in the process of inserting

15.5 F ASPIRA drainage tube

15.5 F Aspira catheter
  • The remote can be cut to fit the smaller cavity
  • The proximal adjustment in order to realize the valve replacement
Other components include:

dilator

18 g needle

0.038 "x 80 cm J - Tip thread

The slide clamp

Can be connected suture wing

scalpel

The ruhr adapter

General pipe joint

ASPIRA suite components

Insert the tray components

1-15.5 F peritoneal and pleural drainage catheter, with a probe
1 - # 11 Futura ® safety scalpel
1-18 g needle
1-0.038 inches x 80 cm godet J type
1 -dilator8 f
1 -dilator12 f
1-16.5 F, detachable sheathed into the device
1 - tube tunnels
1 - slide clamp
1 - Aspira valve components
1 - Aspira cover
1 - suture wing
1 - the ruhr adapter
1 - general pipe joint
2 - split gauze 4 "x 4" (10 cm x 10 cm)
6-4 "x 4" (10 cm x 10 cm)
1 - surgical tape
1 - adhesive dressings


Change suite components

1 - adhesive dressings
2 - split gauze 4 "x 4" (10 cm x 10 cm)
4, 4 "x 4" (10 cm x 10 cm)
1 - gloves (1)
Article 1 - tape (each 3)
3 - alcohol to wipe
1, corporate social responsibility


Drainage suite components

The drainage bag of 1 - (1000 ml)
2 - alcohol to wipe
1 - slide clamp
Article 1 - tape (each 3)
1 - Aspira cover


The ruhr adapter component

1 - the ruhr adapter
1 - Aspira cover


General coupling components

1 - general pipe joint
1 - Aspira cover


Repair kit components

1 - slide clamp
1 - Aspira valve components
1 - Aspira cover


reference

  1. Archives.The inner diameter of the measurement in the narrowest place.Each device N = 10.
  2. Archives.Simulated water drainage.Aspira drainage bag N = 9, PleurX drainage bottle N = 8.Benchmark data that may not represent the clinical results.Different test methods may produce different results.
  3. Archives.Under the condition of similar simulation water drainage.For Aspira drainage bag, N = 40).For PleurX drainage bottle, N = 8.Benchmark data that may not represent the clinical results.Different test methods may produce different results.
  4. The Data on the file.

All trademarks are property of their respective owners.

    The document

    Check the manual and instructions, learn about Aspira drainage system for more information.

    In the load...

    The order information

    Box Quantity Can be Found Here">Container number can beFound here

    Patients with resources

    Patients with video

    Patient guide and brochures

    Patient information

    The trademark